Meine Merkliste
my.bionity.com  
Login  

Dry powder inhalation of Celecoxib nanoparticles

Formulation and in-vitro characterization

The aim of the present study was to develop and optimize Celecoxib (CAS number: 169590-42-5) nanocrystals for pulmonary delivery potential for application in lung cancer. Nanocrystals were prepared by the liquid anti solvent precipitation method using lecithin as a stabilizer. According to the limited number of approved excipients for application in the formulations intended to be used for pulmonary delivery, a narrow range of materials documented as generally recognized as safe (GRAS) excipient such as lecithin and mannitol were used in the present study. The optimized formulation in the size of 79 nm was co-spray dried with varying amounts of mannitol to form aggregated nanocrystals appropriate for application in drug delivery to the lung. The aerosolization efficiency of dry powders was determined by next generation impactor (NGI). The amount of Celecoxib in the stages of NGI was measured by an HPLC technique developed by the authors. The results of different formulations showed around 4 % fine particle fraction (FPF). The low melting point and hygroscopic characteristic of lecithin might be responsible for the observed not ideal aerosolization performance of formulations. The obligation in application of just few excipients in the formulations for pulmonary administration creates the challenge of being open while at the same time preparing efficient formulations for pulmonary delivery.

Autoren:   Shadi Yaqoubi, Mohammad Barzegar-Jalali, Khosro Adibkia, Hamed Hamishehkar
Journal:   pharmind
Band:   77
Ausgabe:   11
Jahrgang:   2015
Seiten:   1652
Erscheinungsdatum:   01.11.2015
Fakten, Hintergründe, Dossiers
  • Celecoxib
  • lung cancer
  • Inhalation
Mehr über ECV
  • Fachpublikationen

    Serie: Druckluft in der pharmazeutischen Industrie

    Teil  1: Wichtige GrundlagenDie Hauptforderungen an eine Druckluftversorgung sind höchstmögliche Verfügbarkeit bei gleichzeitiger Energie- und Kosteneffizienz über den gesamten Lebenszyklus eines Druckluftsystems hinweg. Energieverbrauchs- und Kostenanalyse, Kostenplanung und laufendes -man ... mehr

    Reinigung von Anlagen

    In der Anlagentechnik unterscheidet man generell 3 Arten von CIP-Systemen, die abhängig vom Einsatzzweck spezifische Vor- und Nachteile aufweisen (Abb.  4). mehr

    Schweißen in der Pharmazie

    Na(ht) – alles klar?Aus der Distanz sieht jede Schweißnaht gleichartig aus. Jedoch ist grundsätzlich jede Schweißnaht individuell zu bewerten. Das mag manchen Leser erstaunen: Schließlich sind die Verfahren bewährt, die Parameter erprobt, alle Randbedingungen identisch. Allerdings kann jede ... mehr

Ihr Bowser ist nicht aktuell. Microsoft Internet Explorer 6.0 unterstützt einige Funktionen auf Chemie.DE nicht.