Mit einem my.bionity.com-Account haben Sie immer alles im Überblick - und können sich Ihre eigene Website und Ihren individuellen Newsletter konfigurieren.
We present a computational framework for multiscale modeling and simulation of blood flow in coronary artery bypass graft (CABG) patients. Using this framework, only CT and non-invasive clinical measurements are required without the need to assume pressure and/or flow waveforms in the coronaries and we can capture global circulatory dynamics. We demonstrate this methodology in a case study of a patient with multiple CABGs. A patient-specific model of the blood vessels is constructed from CT image data to include the aorta, aortic branch vessels (brachiocephalic artery and carotids), the coronary arteries and multiple bypass grafts. The rest of the circulatory system is modeled using a lumped parameter network (LPN) 0 dimensional (0D) system comprised of resistances, capacitors (compliance), inductors (inertance), elastance and diodes (valves) that are tuned to match patient-specific clinical data. A finite element solver is used to compute blood flow and pressure in the 3D (3 dimensional) model, and this solver is implicitly coupled to the 0D LPN code at all inlets and outlets. By systematically parameterizing the graft geometry, we evaluate the influence of graft shape on the local hemodynamics, and global circulatory dynamics. Virtual manipulation of graft geometry is automated using Bezier splines and control points along the pathlines. Using this framework, we quantify wall shear stress, wall shear stress gradients and oscillatory shear index for different surgical geometries. We also compare pressures, flow rates and ventricular pressure–volume loops pre- and post-bypass graft surgery. We observe that PV loops do not change significantly after CABG but that both coronary perfusion and local hemodynamic parameters near the anastomosis region change substantially. Implications for future patient-specific optimization of CABG are discussed.
Autoren:
Sethuraman Sankaran, Mahdi Esmaily Moghadam, Andrew M. Kahn, Elaine E. Tseng, Julius M. Guccione, Alison L. Marsden
Endothelial nitric oxide synthase polymorphism G298T in association with oxidative DNA damage in coronary atherosclerosis
Content Type Journal Article
Category Research Note
Pages 1-4
DOI 10.1007/s12041-012-0183-1
Authors
RAJESH G. KUMAR, Department of Genetics, Osmania Univers ... mehr
A micropropagation protocol was developed for multiplication of seedless lemon (Citrus limon L. cv. Kaghzi Kalan) using nodal explants. The maximum shoot regeneration was observed on low level of BAP (0.1 mg l−1) or kinetin (0.5 mg l−1). BA was recorded to be better than kinetin in terms of ... mehr
The objective of this study was to evaluate the activity, kinetic behavior, and thermal inactivation kinetics of peroxidase (POD) in aqueous extracts from two kinds of milk ripe stage corn, sweet corn and waxy corn. Optimum activities using guaiacol as the hydrogen donor were obtained for s ... mehr
Die Max-Planck-Gesellschaft und Springer haben sich einvernehmlich darauf verständigt, den Wissenschaftlern aller Max-Planck-Institute und Forschungsgruppen den Zugriff auf sämtliche Inhalte der Onlineplattform SpringerLink zu ermöglichen.
Die Vereinbarung umfasst auch Open ChoiceTM, das O ... mehr
Mit mehr als 18.000 elektronischen Laborprotokollen in den Bereichen Life Sciences und Biomedizin hat der Wissenschaftsverlag Springer sein Online-Angebot für Forschungslabors erheblich ausgebaut. Unter dem Namen Springer Protocols finden Wissenschaftler aus Forschungsinstitutionen und Unte ... mehr
Die Max-Planck-Gesellschaft hat nach schwierigen Verhandlungen ihren langjährigen Lizenzvertrag mit dem Springer Verlag zum 31. Dezember 2007 gekündigt. Die Verhandlungen sind gescheitert, weil laut MPG keine Einigung über ein adäquates Verhältnis von Preis und nachhaltigen Leistungen erzie ... mehr