Fig. 1 shows schematically the production process of coated ELISA plates in a 3 step and in a 2 step process. Basically the steps mentioned are identical independent of immobilized capture antibodies or antigens. In diagnostics manufacturing it was well established over decades to stabilize with sugar or carbohydrate containing solutions. These “homemade” formulations were the first generation of stabilizer solutions. These solutions show in many assays sufficient storage stability if continued refrigeration was provided. In addition to these homemade stabilizer solutions there are also some coating stabilizers on the market. These commercially available solutions of the second generation have two advantages: First you can save one step by doing blocking and stabilizing in one step without loosing too much of reliability. Second you can get better and longer stability. This is important if you have unstable antibodies. In particular monoclonal antibodies often show low stability on surfaces. But also polyclonal sera can be affected by short shelf-life. The decision for an adequate blocker or stabilizer solution is made during development and validation of a diagnostics product. The EU guidance for in-vitro diagnostics regulates that criteria and activities of the product must not change during lifetime, because of potential risks for the patient’s safety. That means that product characteristics must not change at all during transportation and storage, because every false diagnosis represents a potential risk for patients. Without sufficient stability it is not allowed to sell a diagnostical product on the European market. For important international markets corresponding standards apply. Trends in diagnostics and new challenges Diverse trends influence the development of modern immuno diagnostics. Some of them are exemplified and their effects on the stabilization standards of immuno diagnostics will be described. Trend 1: There is an increasing cost pressure for diagnostics manufacturers in the industry nations. Reasons are political desired cost reduction in health care and more competition due to less discrimination of the diagnostics providers. This leads to a pressure on pricing which can only be met with adaptations in manufacturing. This trend has also an effect on established ELISA kits, because some product and manufacturing changes are necessary to lower the costs of production. During product changes the quality of diagnostics on the market has to be unchanged. Trend 2: The markets of diagnostics in threshold countries grow continuously due to a rising economic status. Concurrently there are lacks of infrastructure in these countries. Trend 3: The medical research always discovers new and suitable molecules for diagnostics. Reasons for the discovery of new biomarkers are better analytics and sample preparation. Modern biomarkers are not easy to discover due to their availability in low concentrations or their short shelf-lives. Most of them even show a combination of both, low concentration and short shelf-life. Requirements on the basis of the trends mentioned above Trend 1: Lower costs of kit components are desirable. This also applies for commercially available stabilizer solutions. New technologies for stabilization must be more efficient. Trend 2: If you also want to serve the strong rising markets of the threshold countries the security stock of the product stability has to be enlarged. Trend 3: Low concentrations of analyte demand so far unknown good precision of immuno diagnostics. Loss in quality during storage like a decreasing amount of functional coated antibodies leads to a bad precision of the ELISA. The detection limit has to be exhausted to the technical maximum to meet the challenges of modern biomarkers. For product developments the stability of the standards becomes more and more important. The requirements for the third generation of stabilizers are the following: Better stability and simultaneously low pricing. The third generation: Liquid Plate Sealer® CANDOR Bioscience is supplier of the diagnostics industry and developer of innovative tools for immunoassays. CANDOR can meet the demands mentioned above with the new product Liquid Plate Sealer®. Liquid Plate Sealer® shows an outstanding stabilization of antibodies and antigens after immobilization. A measurable reactivation can also be observed as well as a very good and reproducible blocking. Additionally Liquid Plate Sealer® is more economic compared to the well-established market-dominating stabilizers of the second generation. Liquid Plate Sealer® can be used in production of immuno diagnostics like other stabilizers. After coating, the plates are incubated with Liquid Plate Sealer®. After removing the stabilizer the plates can be dried and stored for long-term periods. Shelf-lives up to several years are possible even with instable antibodies. Stress tests show this by conservative correlation according to Arrhenius. In addition Liquid Plate Sealer® makes it possible for any life science lab to store plates under moist conditions in the fridge. Such stored plates keep stable for several weeks up to several months (dependent on used antibodies). This is a good assistance for research applications where a classical ELISA production is not profitable. Often the equipment like an oven or heat-sealer also does not exist in these labs. The increased stability compared to three stabilizers of the second generation from the market leader has been quantified. Although the second generation of stabilizers show very good results, CANDOR could enhance these results. The costs for Liquid Plate Sealer® are not higher than for the competitive products. Liquid Plate Sealer® is „made in Germany” and available from 50 ml for any lab to bulk quantities to manufacturers of test kits. Mode of action Liquid Plate Sealer® seals the coated biomolecules with an uniform and stabilizing but easy soluble layer. During incubation the coated antibodies are surrounded by a protective layer. Even some inactive and non-binding antibodies recover their binding ability and can give a measurement signal. In many cases the amount of functional capture antibodies increases because of reactivation of antibodies. Once activated most antibodies stay stable below the protective layer over long periods even under temperature stress. This allows ELISA which can better tolerate broken cold chains. Activation takes place by components which have an impact on the protein conformation. The negative influence of the plastics surface towards the proteins can be weakened. The generated protection layer prevents folding to an inactive conformation even under temperature stress. Altogether Liquid Plate Sealer® provides an active (reactivation) as well as a passive (stabilization of conformation) protection system for coated molecules. If you use the plate in an ELISA you can add the samples without further washing steps. The established ELISA procedure does not have to be changed. The user of an ELISA only recognizes the longer stability of the plates treated with Liquid Plate Sealer®. Exchanging commercial stabilizers of the second generation with stabilizers of the third generation is mostly practicable without changes in manufacturing processes or products. Comparative stress tests – mandatory for clinical diagnostics – show stability data achieved with Liquid Plate Sealer®. Stress testing Fig. 2 shows the results of a stress test at 45°C with an unstable antibody. This antibody shows after 1 day of storage with a sugar containing stabilizer solution an extremely reduced signal in the ELISA. This antibody is well suited to show the qualitative differences between the 3 stabilizer generations.
Results after stabilization are shown in comparison to 3 competitor products of the second generation and Liquid Plate Sealer®. Applications and procedures of coating and measuring have been identical. If coating stabilizers of the second generation were used in production, switching to Liquid Plate Sealer® can be done very easily. Liquid Plate Sealer® is also suitable for applications which need an efficient blocking. It can be used not only in a two step production but also in the above shown 3 step production. It is compatible with all blockers tested so far. Stabilization in combination with the widely-used BSA blocking is shown exemplarily in fig. 3. You can see the drift of the calibration curve during storage when the plate is not stabilized. Calibration curves are only useful over the whole period when plates are stabilized. This stabilized ELISA would also achieve reproducible results after 84 days at 37°C.
Fig 4 shows the combination of different blockers with Liquid Plate Sealer® (3 step processing) and blocking and stabilization only with Liquid Plate Sealer® (2 step processing). One can see that the combination with many blockers is possible if needed.
Applications Liquid Plate Sealer® is used for industrial production of coated ELISA plates, immunochromatographic strips (lateral flow devices), affinity columns and other commercial products. Outlook Liquid Plate Sealer® was the first product of the immunoassay stabilizer solution series from CANDOR on the market. In the meantime a number of stabilizer solutions like HRP-Protector™ and LowCross-HRP® are available. Both are stabilizers for peroxidase which show an outstanding stabilization of peroxidase conjugates. LowCross-HRP® combines peroxidase stabilization with the LowCross effect. Thus interferences from HAMAs (human mouse antibodies), other heterophilic antibodies and cross reactivities can be avoided. These stabilizers enable long-term storage of detection antibodies coupled to peroxidase in end-user concentrations. Further dilution steps by the end-users are not necessary. The stabilizer series of CANDOR will be supplemented by stabilizers of alkaline phosphatase and protein standards in solution. All products of CANDOR are available in bulk quantities and are manufactured according to the DIN EN ISO 9001:2000 certification. Additional information
Articles
Products
|
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Product of the Week |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||